Template-Type: ReDIF-Article 1.0 Author-Name: Arthur Grimes, Nicholas Preval, Chris Young, Richard Arnold, Tim Denne, Philippa Howden-Chapman, and Lucy Telfar-Barnard Title: Does Retrofitted Insulation Reduce Household Energy Use? Theory and Practice Classification-JEL: F0 Volume: Volume 37 Issue: Number 4 Year: 2016 Abstract: We analyze the household energy use impacts of a large-scale, universally available, subsidized retrofit insulation and clean heat scheme. Theory shows that the energy-saving effects of such schemes are ambiguous. Our difference-in-difference model of energy impacts resulting from each of insulation and clean heat treatment uses a sample of more than 12,000 treated houses. Retrofitted insulation treatment under the Warm Up New Zealand: Heat Smart program resulted in a statistically significant reduction in metered household energy consumption of almost 2%. Clean heat (heat pump) treatment resulted in increased electricity use but little change in total metered energy use other than at warmer temperatures, when heat pumps may have been used as air conditioners. Actual energy savings from insulation are approximately one-third of the modeled energy savings predicted by an engineering model. Handle: RePEc:aen:journl:ej37-4-Grimes File-URL: http://www.iaee.org/en/publications/ejarticle.aspx?id=2807 File-Format: text/html File-Restriction: Access to full text is restricted to IAEE members and subscribers.